Single-Zone Universal Telephone Interface UTI1

Model UTI1 - Single-Zone Universal Telephone Interface

 

*NOTE* The TAMB2/PS is now EOS. The UTI1 is a great substitute for 95% of use cases. See the documentation section below for a full feature comparison guide. 

Bogen’s UTI1 is a single-zone telephone interface that is compatible with all standard analog port types. A background music (BGM) input with variable  muting coordinates music and page announcements. An additional audio output provides a “page only” function (no BGM) for application flexibility. A built-in 24V DC, 1A power supply is provided for powering amplified speakers. Paging volume controls are provided for each of the outputs. Contact-triggered tones and night ring signals, as well as programmable AUX relay contacts, are  all programmed using DTMF tones through the dual-purpose override input. 

  • Emergency override and general paging
  • Interfaces to Loop Start, Ground Start, Analog Station, and Page Ports (with or without contact closure activation)
  • Background music (BGM) input with level control and variable muting
  • Separate Page and BGM and Page Only
  • Level control for each output
  • 24V DC, 1A power supply
  • 150 Speaker T/R drive capacity per output
  • Page level limiter with active indicator
  • Override input (loop start or page port)
  • Programmable timeout for station
  • Tone burst (2 to 7 sec), chime, and whoop tone selections
  • Micro-controller operated, DTMF programmable
  • Night ring tone or chime selection
  • Programming through override
  • Wall-mount design
  • FCC Part 68 Registered
  • Listed to UL Standard 60950 for U.S. and Canada